Filter Results By:

Products

Applications

Manufacturers

D/A Converters

Transform digital signals to analog.


Showing results: 61 - 75 of 287 items found.

  • Angular Orientation Sensor

    WOS-120 - Wuntronic GmbH

    The Miniature Angular Orientation Sensor system Model WOS-120 contains both a 3-axis fluxgate magnetometer and a 3-axis accelerometer. These sensors are sampled by an internal A to D converter and microprocessor subsystem which outputs 16 bit digital data representing the magnetometer and accelerometer readings. The system can also be configured to transmit the roll, pitch and azimuth orientation angles of the Model WOS-120 system. These angles are calculated before transmission from the accelerometer and magnetometer sensor output data.

  • SparkFun I2S Audio Breakout

    MAX98357A - SparkFun Electronics

    The SparkFun I2S Audio Breakout board uses the MAX98357A digital to analog converter (DAC), which converts I2S (not be confused with I2C) audio to an analog signal to drive speakers. The I2S Audio Breakout converts the digital audio signals using the I2S standard to an analog signal and amplifies the signal using a class D amplifier which can deliver up to 3.2W of power into a 4Ω load. The board can be configured to output only the left channel audio, right channel, or both.

  • Miniature Airborne Communications Converter

    MACC II - Converter - Excalibur Systems, Inc.

    Excalibur’s MACC II represents a third option. A proven, low risk, low cost, off the shelf product that translates between different communications specifications. The MACC II can solve your communications problems without R&D costs and without schedule risks while still providing you with the flexibility to customize the system to your specific needs.The MACC II is a wholly contained Miniature Airborne Communications Converter (data converter - protocol converter or translator). The MACC II can carry up to 4 modules. Each module can be one of the following protocols: 1 dual redundant MIL-STD-1553/1760 interface1 H009 channel5 MMSI channels5 ARINC-429 channels2 ARINC-708 channels2 ARINC-717 channels5 ARINC-825 (canbus) channels2 Serial channels (RS-232/422/485, NMEA 0183)Ethernet (10/100/Gigabit)10 Discrete I/O signalsAnalog to Digital / Digital to AnalogPlease see multi protocol 8000 modules for additional information on protocols that can be used on the MACC II.

  • 8 Channel 14 Bit 3 MSPS VME Analog Input Card

    PAS 9732/AI - Precision Analog Systems Co.

    The PAS 9732/AI is a VME based, eight channel, 14 bit, 3 MHz per channel, Analog Input Card. This card can be used in VME systems with A16, A24, or A32 addressing, and data bus widths of 16 and 32 bits are supported. Jumper plugs are used to configure the width of the address and data buses. Eight high speed Analog to Digital Converters (ADCs) with 3 MHz conversion rates continuously scan the analog input signals, which are connected to a 25 pin D connector mounted through the front panel.

  • 6U PXI Multi-Channel Analog I/O PXI Card

    GX3348 Series - Marvin Test Solutions, Inc.

    The GX3348 is a multi-channel analog I/O 6U PXI card which provides (3) programmable sources, a ground source connection, a pulse / square wave generator (A version only) and a 4 x 48 or 4 x 64 matrix - allowing the user to route the 3 sources, or ground to any of the 48 or 64 I/O channels. In addition, each I/O channel can be connected to a 16-bit A to D converter, providing DC voltage measurement capability for each channel. The module also offers (8) static digital I/O for controlling / monitoring a UUT's digital signals.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL D - Tenma

    The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Multi-Protocol Analyzer / Generator

    780E - Teledyne LeCroy quantumdata

    The Quantum Data 780E Multi-Protocol Analyzer / Generator is a handheld digital video generator and analyzer that enables you to run tests on various digital video devices and network distribution devices on site or in the R&D lab. The 780E instrument provides a 7 inch color touch screen for operation and for viewing status of outgoing and incoming video and audio. The 780E is equipped with DisplayPort, HDMI and HDBaseT interfaces. Each digital interface is supported by both an output port and an input port to allow testing of digital video sources, displays, audio devices and distribution devices. Testing hybrid converter devices supporting DisplayPort, HDMI, HDBaseT distribution networks is a key application of the 780E as well.

  • Handheld Digital Video Generator and Analyzer

    780C - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 780C is a handheld digital video generator and analyzer that enables you to run tests on various digital video devices and network distribution devices on site or in the R&D lab. The 780C instrument provides a 7 inch color touch screen for operation and for viewing status of outgoing and incoming video and audio. The 780C is equipped with multiple interface types including HDMI, HDBaseT, 3G-SDI and component analog. Testing digital interfaces is supported by both an output port and an input port to allow testing of digital video sources, displays, audio devices and distribution devices. Testing hybrid converter devices supporting 3G-SDI, HDMI, HDBaseT distribution networks is a key application of the 780C as well.

  • 16 or 32 channel Digital to Analog Converter

    LS-71-P - Lumistar Inc.

    The LS-71P PCI D/A Converter (DAC) board provides high speed analog outputs of PCM decommutated data allowing real time data displays using strip chart recorders or similar devices. The LS-71-P board is designed to be used in conjunction with the Lumistar LS-50-P Multifunction PCM Decommutator boards and uses an over-the-top communication bus directly from the decom to the DAC to avoid any glitches in the analog outputs due to PCI bus activity. Direct “mailbox” type access is also provided to allow the user to send information through the PCI bus to the DACs. The DAC board design allows 2 LS-50-D Multifunction decom boards to be used with a single DAC board allowing tagged data from either data stream to be directed to any DAC channel. An optional LS-71-DB Word Selector Daughterboard allows two additional data streams to be monitored with the ability to select channels from 4 data streams to be displayed on any DAC channel. The design incorporates an extremely large memory (more than 200,000 16-bit words) used as a lookup table allowing linear or non-linear EUconversions with constant delay regardless of the number of polynomial coefficients required. Standard product supports a single decom, however, dual decom support is available as an option.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY

    xPS Series - Carl E. Holmes Company

    High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • Data Converters

    Renesas Electronics Corp.

    Renesas' data converter portfolio features precision SAR and delta-sigma A/D converters, high-speed A/D converters with 8 to 16-bit resolutions and 40MSPS to 500MSPS sample rates, a wide selection of low-to-high resolution digital potentiometers (DCPs), and a wide range of precision voltage references in both FGA™ and Band-Gap technology. Other D/A converters are here.

  • DC Electronic Load

    M9822/M9822B - Lisun Electronics Inc.

    M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the minor change of voltage and current, so the instrument has a wider application field and achieves better test results. Meanwhile your operation becomes much more comfortable and easy by equipping the high-light VFD, the simple menu and displayed contents and the operation state indicators on all keys. Otherwise the complete and humanized test functions will greatly improve your productivity.

  • Diaphragm Seal for DA Series Pressure Switch

    XTBX - Dwyer Instruments Inc.

    The Series XTBX is a diaphragm seal constructed of PVC and FEP making it perfect for corrosive applications that would damage metal wetted material pressure switches. The seal is available direct mounted on all model DA pressure switches with ranges under 100 psi (6.9 bar). Ideal for commercial pool/spa applications for pump shut down due to excessive vacuum.

Get Help